Custom On-Site

SDMyers offers the same industry-leading training, delivered by the same transformer maintenance experts, on-site at your company location.

Bring the knowledge and expertise from the finest transformer maintenance training right into your facility. With onsite training from SDMyers, you can save your company substantial costs for attendee travel expenses, including airfare, hotels, and meals, and by reducing how long key employees are away from your operation.

Onsite training helps you standardize maintenance procedures by providing consistency in training for all your employees.

Our instructors can teach as many staff members as needed. Just provide the space and the seating and we’ll do the rest. Onsite seminars are available internationally; we have presented all over the world for various clients, in some cases with real-time translation.

Get in touch with Traci Hopkins via email or by calling 330.630.7000 x. 3485 for more information about on-site training at your location.

on-Site COURSE OPTIONS


Transformer Management 1 (3-DAY COURSE)

This course provides a foundational understanding of the internal and external elements of the transformer, the essentials of transformer operation and maintenance implementation and related industry standards. It covers the chemical, mechanical and electrical components of the transformer, the purpose and operating characteristics of these components, the significant requirements and methods for maintenance, and the major testing involved in maintenance. *Onsite custom pricing available

View Details & Locations
Principles of Transformer Maintenance (2-DAY COURSE)

This course introduces the student to a range of topics summarizing the fundamentals of transformers and transformer maintenance including basic electric concepts, introduction to transformers, solid and liquid insulation, oil testing and analysis, basic electrical testing, and maintenance. Students can bring their own transformer oil test data to use as a class case study and/or get personalized assistance from an instructor. *Onsite custom pricing available

View Details & Locations
Inspection & Sampling of Fluid-Filled Transformers (1/2 DAY COURSE)

In this 1/2-day course, you will learn the proper and safe procedures needed to obtain a representative sample of dielectric fluid. Features a sampling demonstration and practical exercises to obtain accurate oils samples for use in lab analysis. *Onsite custom pricing available

View Details & Locations
Electrical Testing - Power Factor Testing (1-Day Course)

This is a one-day class that gives an in depth understanding of Power Factor Testing in the field. The Power Factor is a measurement of the efficiency of the transformer's insulation system and therefore a reliable electrical test to detect deterioration that may cause significant issues with the operation of the transformer. *Onsite custom pricing available

View Details & Locations
Load Tap Changer Principles & Maintenance (1-DAY COURSE)

This class explains the theory of load tap changing and identifies the various types and styles of tap changers, their components, and sequences of operation. Additionally, this class discusses monitoring, inspections, and testing required for developing an intelligent preventative load tap changer (LTC) maintenance program. *Onsite custom pricing available

View Details & Locations
Advanced DGA Diagnostics (1-DAY COURSE)

Learn to identify fault gases and what causes their formation. We will explain and provide examples of qualitative and quantitative interpretation of dissolved gases and how to evaluate the condition of cellulose insulation. This class will also examine the role DGA plays in new oil testing and discuss procedures to obtain a representative sample from transformers. *Onsite custom pricing available

View Details & Locations
Principios de Mantenimiento de Transformadores (2-Días Curso)

Este curso introduce al alumno en una serie de temas que resumen los fundamentos básicos de los transformadores y de mantenimiento del transformador.  *PreciosEspecializados para Entrenamientos En Sitio

View Details & Locations
Inspección y Muestreo de Transformadores (1-DAY COURSE)

En este curso le enseñará los procedimientos adecuados y seguros necesarios para obtener una muestra representativa del fluido dieléctrico.  *PreciosEspecializados para Entrenamientos En Sitio

View Details & Locations
Gestión de Transformadores 1 (3-DAY COURSE)

Gestión de Transformadores 1 proporciona una comprensión esencial para aquellos que tienen bajo su responsabilidad el mantenimiento de transformadores. Los estudiantes van a obtener un conocimiento fundamental de transformadores, pruebas al aceite, pruebas eléctricas, principios de mantenimiento y la importancia de un sistema eléctrico confiable.  *Precios Especializados para Entrenamientos En Sitio

View Details & Locations
Risk Assessment and Asset Management (1) (1-DAY COURSE)

This course will provide training and education to those responsible for identifying, assessing and mitigating risks associated with distribution and power transformers.  Risk Assessment and Asset Management follows the ISO 55000 standard for asset management. 

View Details & Locations
Risk Assessment for Fluid-Filled Transformers

This class is designed especially for insurance underwriters and agents, field inspectors and risk-control specialists.  This course follows IEEE guides and standard with specific technical guidance.

View Details & Locations
Complete Transformer Maintenance (4-DAY COURSE)

This is a 4-day course presented at the Electric Power Training Center operated by WAPA in Golden, CO.  During the four days, the student will be introduced to important concepts in the effective maintenance and management of one of the most critical components of the electrical system, the transformer. It covers chemical, mechanical and electrical components of the transformer, significant requirements and methods for maintenance, provides the fundamentals to calculate key factors of transformer dry out procedures, provides understanding of the operation and application of processing equipment (i.e. reclamation rigs) and the regasketing and selection of all key gasket materials on a transformer.

View Details & Locations
GET IN TOUCH If you would like us to travel to your location, please call 330.630.7000 x. 3485 or email traci.hopkins@sdmyers.com for more information about on-site training at your location. Contact Us
Please wait while logging in.