Transformer Management Essentials Load Tap Changer Principles & Maintenance
Dates
November 13 - 16, 2018
Registration Cost
$2,250.00 USD
Register
Group Discounts Available.
Call 330.630.7000 x3485 for group pricing

Individual Training Options

Transformer Management Essentials

Transformer Management Essentials

Scheduled Courses

Days: November 13 - 15, 2018

Credits: 2.1 CEU / 21 PDH / 21 NETA CTD

Cost:$1,600.00 USD

Load Tap Changer Principles & Maintenance

Load Tap Changer Principles & Maintenance

Scheduled Courses

Day: November 16, 2018

Credits: 0.7 CEU / 7 PDH / 7 NETA CTD

Cost:$800.00 USD

Day 1 - Day 3

Transformer Management Essentials (formerly Half-Century Transformer)

This course provides a foundational understanding of the internal and external elements of the transformer, the essentials of transformer operation and maintenance implementation and related industry standards. It covers the chemical, mechanical and electrical components of the transformer, the purpose and operating characteristics of these components, the significant requirements and methods for maintenance, and the major testing involved in maintenance. *Onsite custom pricing available

What You'll Learn

  • The role of transformers in power transmission and distribution
  • Transformer design and assembly
  • The transformer aging process
  • Common dielectric fluid tests
  • Interpreting test results (mineral oils)
  • Common field electrical tests and their purpose
  • Predictive, preventative and reactive maintenance
  • Chemical, mechanical and electrical maintenance procedures
  • Equipment condition assessments
  • and more…

Contact SDMyers for on-site training options for your organization.

Day 4

Load Tap Changer Principles & Maintenance

This class explains the theory of load tap changing and identifies the various types and styles of tap changers, their components, and sequences of operation. Additionally, this class discusses monitoring, inspections, and testing required for developing an intelligent preventative load tap changer (LTC) maintenance program. *Onsite custom pricing available

What You'll Learn

  • Identify the purpose of load tap changers.
  • Identify load tap changer components.
  • Identify the sequence of operation, including those with vacuum interrupters.
  • Learn monitoring and testing procedures.
  • Review of inspection and testing procedures.
  • Develop a preventative maintenance program for LTCs.

Contact SDMyers for on-site training options for your organization.